Inverter List

Inverters

ABB UNO-7.6-TL-OUTD-S-US-A

ABB inverters · String

ABB UNO-7.6-TL-OUTD-S-US-A is a string inverter on California's eligible inverter list in 3 voltage options: 7.6 kW continuous output and 97% weighted efficiency at 208, 240, and 277 V. Listed since Jul 1, 2017.

Recorded installations

Systems matched to this model
629
Installation years
2014–2025
States represented
8

Counts cover matched records in a partial US sample. One system can name more than one model. They do not measure reliability or current sales.

Installed solar-system price

Median dollars per DC watt
$3.86/W
Priced systems
86

The median covers whole, host-owned solar systems without storage, across the years above. It is not the inverter's price or a quote for your home. Prices are not adjusted for inflation. Price method and scope.

Listed figures by voltage option

California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.

UNO-7.6-TL-OUTD-S-US-A {240V}

UNO-7.6-TL-OUTD-S-US-A {240V} listed figures
AC voltage (V)240
Continuous output (kW)7.6
Weighted efficiency (%)97
Night draw (W)1.4
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)200
Test DC voltage, nominal (V)380
Test DC voltage, maximum (V)480
Supplement SB flagNo
Grid profile flagN
Listing dateJul 1, 2017
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum93.195.796.396.696.596.3
Nominal95.497.197.597.797.697.4
Maximum93.996.597.197.497.497.2

UNO-7.6-TL-OUTD-S-US-A {208V}

UNO-7.6-TL-OUTD-S-US-A {208V} listed figures
AC voltage (V)208
Continuous output (kW)7.6
Weighted efficiency (%)97
Night draw (W)1.3
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)200
Test DC voltage, nominal (V)340
Test DC voltage, maximum (V)480
Supplement SB flagNo
Grid profile flagN
Listing dateJul 1, 2017
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum93.99696.496.596.496.1
Nominal95.697.197.497.497.397
Maximum93.896.396.897.19796.7

UNO-7.6-TL-OUTD-S-US-A {277V}

UNO-7.6-TL-OUTD-S-US-A {277V} listed figures
AC voltage (V)277
Continuous output (kW)7.6
Weighted efficiency (%)97
Night draw (W)1.5
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)200
Test DC voltage, nominal (V)380
Test DC voltage, maximum (V)480
Supplement SB flagNo
Grid profile flagN
Listing dateJul 1, 2017
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum92.195.396.196.696.696.4
Nominal93.996.49797.497.497.3
Maximum94.296.797.397.797.797.7

Maker or retailer figures

No publishable maker or retailer figures are held for this model. Figures may be published elsewhere.

Stored retail listings

No stored retail listing is held for this model.

Not covered

Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.