Inverter List

Inverters

Enphase IQ6PLUS-72-2-US

Enphase inverters · Microinverter

Enphase IQ6PLUS-72-2-US is a microinverter on California's eligible inverter list in 2 voltage options: 280 W continuous output and 97% weighted efficiency at 208 and 240 V. Listed since Aug 1, 2017.

Recorded installations

Systems matched to this model
1,289
Installation years
2017–2025
States represented
10

Counts cover matched records in a partial US sample. One system can name more than one model. They do not measure reliability or current sales.

Installed solar-system price

Median dollars per DC watt
$3.38/W
Priced systems
949

The median covers whole, host-owned solar systems without storage, across the years above. It is not the inverter's price or a quote for your home. Prices are not adjusted for inflation. Price method and scope.

Listed figures by voltage option

California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.

IQ6PLUS-72-2-US {208V}

IQ6PLUS-72-2-US {208V} listed figures
AC voltage (V)208
Continuous output (kW)0.28
Weighted efficiency (%)97
Night draw (W)0.02
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)27
Test DC voltage, nominal (V)36
Test DC voltage, maximum (V)45
Supplement SB flagNo
Grid profile flagY*
Listing dateAug 1, 2017
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.6361496.3400796.9302297.3761297.1424696.5786
Nominal94.5628795.6844596.4510397.1496897.0920296.68381
Maximum93.9288995.027195.9707396.9185196.9130896.59496

IQ6PLUS-72-2-US {240V}

IQ6PLUS-72-2-US {240V} listed figures
AC voltage (V)240
Continuous output (kW)0.28
Weighted efficiency (%)97
Night draw (W)0.03
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)27
Test DC voltage, nominal (V)36
Test DC voltage, maximum (V)45
Supplement SB flagNo
Grid profile flagY*
Listing dateAug 1, 2017
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.2530696.1631296.8171197.3026197.1455996.71648
Nominal94.5548495.744496.2814297.254997.3334197.17007
Maximum93.9058895.090195.7449396.9719897.1486897.03843

Maker or retailer figures

Published figures and their conditions
PropertyValueUnitBasis and scopeDocument
Rapid shutdown UL Listed as PV rapid shutdown equipment, NEC 690.12—Code claim · US · this model
IQ6PLUS-72-2-US
section 690.12
Enphase Energy document
Recorded Oct 12, 2026
Efficiency 97%California weighted · US · this model
IQ6PLUS-72-2-US {240V}
Enphase Energy document
Recorded Oct 12, 2026
AC power 0.28kVAContinuous · US · this model
IQ6PLUS-72-2-US
Maximum continuous output power
Enphase Energy document
Recorded Oct 12, 2026
Efficiency 97%California weighted · US · this model
IQ6PLUS-72-2-US {208V}
Enphase Energy document
Recorded Oct 12, 2026
AC power 0.29kVASurge · US · this model
IQ6PLUS-72-2-US
Peak output power
Enphase Energy document
Recorded Oct 12, 2026

Stored retail listings

A stored listing is not a current stock or price check.

Not covered

Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.