Inverter List

Inverters

Enphase IQ7PLUS-72-ACM-US

Enphase inverters · Microinverter

Enphase IQ7PLUS-72-ACM-US is a microinverter on California's eligible inverter list in 2 voltage options: 290 W continuous output and 97% weighted efficiency at 208 and 240 V. Listed since Jun 1, 2021.

Recorded installations

Systems matched to this model
2,573
Installation years
2017–2025
States represented
9

Counts cover matched records in a partial US sample. One system can name more than one model. They do not measure reliability or current sales.

Installed solar-system price

Median dollars per DC watt
$3.59/W
Priced systems
2,157

The median covers whole, host-owned solar systems without storage, across the years above. It is not the inverter's price or a quote for your home. Prices are not adjusted for inflation. Price method and scope.

Listed figures by voltage option

California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.

IQ7PLUS-72-ACM-US {208V}

IQ7PLUS-72-ACM-US {208V} listed figures
AC voltage (V)208
Continuous output (kW)0.29
Weighted efficiency (%)96.5
Night draw (W)0.025
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)27
Test DC voltage, nominal (V)36
Test DC voltage, maximum (V)45
Supplement SB flagYes
Grid profile flagY*
Listing dateJun 1, 2021
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.9112596.2467197.1080697.2516596.9256696.29417
Nominal93.9563295.314596.7281797.1586796.9578296.44501
Maximum93.147994.5899696.3899496.9798296.8592196.37339

IQ7PLUS-72-ACM-US {240V}

IQ7PLUS-72-ACM-US {240V} listed figures
AC voltage (V)240
Continuous output (kW)0.29
Weighted efficiency (%)97
Night draw (W)0.025
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)27
Test DC voltage, nominal (V)36
Test DC voltage, maximum (V)45
Supplement SB flagYes
Grid profile flagY*
Listing dateJun 1, 2021
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum95.0036496.2456797.147797.4290797.1640696.60387
Nominal94.1619695.5751796.7802497.4952997.4428297.1569
Maximum93.3214194.8058996.3940297.2731697.3095197.07574

Maker or retailer figures

No publishable maker or retailer figures are held for this model. Figures may be published elsewhere.

Stored retail listings

No stored retail listing is held for this model.

Not covered

Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.