Eternalplanet HNA2-S11G5
Eternalplanet inverters · Hybrid-listed
Eternalplanet HNA2-S11G5 is a hybrid-listed inverter on California's eligible inverter list in 7 voltage options: 5.0315–11.34938 kW continuous output and 96–97% weighted efficiency at 208 and 240 V. Listed since Jul 21, 2026.
No recorded installation count is held for this model. A missing count does not mean no installations.
Listed figures by voltage option
California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.
HNA2-S11G5 {208V, 9.9kW}
HNA2-S11G5 {208V, 9.9kW} listed figures| AC voltage (V) | 208 |
|---|
| Continuous output (kW) | 9.9 |
|---|
| Weighted efficiency (%) | 95.5 |
|---|
| Night draw (W) | 19.77 |
|---|
| Output at 40°C (kW) | Not stated |
|---|
| Test DC voltage, minimum (V) | 250 |
|---|
| Test DC voltage, nominal (V) | 360 |
|---|
| Test DC voltage, maximum (V) | 480 |
|---|
| Supplement SB flag | Yes |
|---|
| Grid profile flag | Y* |
|---|
| Listing date | Jul 21, 2026 |
|---|
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|
| Minimum | 94.077267 | 95.7729 | 95.5128 | 95.246067 | 95.217433 | 94.565067 |
|---|
| Nominal | 94.6946 | 96.180033 | 96.353833 | 96.319233 | 95.645233 | 95.1092 |
|---|
| Maximum | 94.0239 | 95.644833 | 95.9748 | 95.892433 | 95.5 | 94.999667 |
|---|
HNA2-S11G5 {240V, 7.6kW}
HNA2-S11G5 {240V, 7.6kW} listed figures| AC voltage (V) | 240 |
|---|
| Continuous output (kW) | 7.6 |
|---|
| Weighted efficiency (%) | 96.5 |
|---|
| Night draw (W) | 20.14 |
|---|
| Output at 40°C (kW) | Not stated |
|---|
| Test DC voltage, minimum (V) | 250 |
|---|
| Test DC voltage, nominal (V) | 375 |
|---|
| Test DC voltage, maximum (V) | 480 |
|---|
| Supplement SB flag | Yes |
|---|
| Grid profile flag | Y* |
|---|
| Listing date | Jul 21, 2026 |
|---|
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|
| Minimum | 93.273933 | 95.6475 | 96.208367 | 96.235833 | 96.088633 | 95.7839 |
|---|
| Nominal | 93.699733 | 95.9983 | 96.639267 | 96.8057 | 96.676767 | 96.4222 |
|---|
| Maximum | 93.478733 | 95.611933 | 96.259833 | 96.568333 | 96.4535 | 96.186967 |
|---|
HNA2-S11G5 {240V, 5.8kW}
HNA2-S11G5 {240V, 5.8kW} listed figures| AC voltage (V) | 240 |
|---|
| Continuous output (kW) | 5.8122 |
|---|
| Weighted efficiency (%) | 96 |
|---|
| Night draw (W) | 20.14 |
|---|
| Output at 40°C (kW) | Not stated |
|---|
| Test DC voltage, minimum (V) | 250 |
|---|
| Test DC voltage, nominal (V) | 375 |
|---|
| Test DC voltage, maximum (V) | 480 |
|---|
| Supplement SB flag | Yes |
|---|
| Grid profile flag | Y* |
|---|
| Listing date | Jul 21, 2026 |
|---|
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|
| Minimum | 91.691467 | 94.9083 | 95.850067 | 96.166167 | 96.283133 | 96.1082 |
|---|
| Nominal | 92.4874 | 95.379367 | 96.2015 | 96.783267 | 96.8356 | 96.708367 |
|---|
| Maximum | 92.002467 | 94.965967 | 95.827533 | 96.509867 | 96.485467 | 96.455433 |
|---|
HNA2-S11G5 {208V, 5.0kW}
HNA2-S11G5 {208V, 5.0kW} listed figures| AC voltage (V) | 208 |
|---|
| Continuous output (kW) | 5.0315 |
|---|
| Weighted efficiency (%) | 95.5 |
|---|
| Night draw (W) | 19.77 |
|---|
| Output at 40°C (kW) | Not stated |
|---|
| Test DC voltage, minimum (V) | 250 |
|---|
| Test DC voltage, nominal (V) | 360 |
|---|
| Test DC voltage, maximum (V) | 480 |
|---|
| Supplement SB flag | Yes |
|---|
| Grid profile flag | Y* |
|---|
| Listing date | Jul 21, 2026 |
|---|
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|
| Minimum | 90.648133 | 94.220467 | 95.284367 | 95.818016 | 95.718967 | 95.6238 |
|---|
| Nominal | 91.4714 | 94.6072 | 95.6642 | 96.233367 | 96.126322 | 96.176333 |
|---|
| Maximum | 91.2682 | 94.504667 | 95.383467 | 95.9362 | 95.969867 | 95.883833 |
|---|
HNA2-S11G5 {240V, 9.6kW}
HNA2-S11G5 {240V, 9.6kW} listed figures| AC voltage (V) | 240 |
|---|
| Continuous output (kW) | 9.63 |
|---|
| Weighted efficiency (%) | 96 |
|---|
| Night draw (W) | 20.14 |
|---|
| Output at 40°C (kW) | Not stated |
|---|
| Test DC voltage, minimum (V) | 250 |
|---|
| Test DC voltage, nominal (V) | 375 |
|---|
| Test DC voltage, maximum (V) | 480 |
|---|
| Supplement SB flag | Yes |
|---|
| Grid profile flag | Y* |
|---|
| Listing date | Jul 21, 2026 |
|---|
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|
| Minimum | 94.1685 | 95.970067 | 96.256033 | 96.196567 | 95.845233 | 95.4484 |
|---|
| Nominal | 94.662767 | 96.326833 | 96.726667 | 96.772 | 96.422 | 95.9912 |
|---|
| Maximum | 94.168833 | 95.994167 | 96.4864 | 96.537233 | 96.284367 | 95.775467 |
|---|
HNA2-S11G5 {208V, 6.6kW}
HNA2-S11G5 {208V, 6.6kW} listed figures| AC voltage (V) | 208 |
|---|
| Continuous output (kW) | 6.68 |
|---|
| Weighted efficiency (%) | 96 |
|---|
| Night draw (W) | 19.77 |
|---|
| Output at 40°C (kW) | Not stated |
|---|
| Test DC voltage, minimum (V) | 250 |
|---|
| Test DC voltage, nominal (V) | 360 |
|---|
| Test DC voltage, maximum (V) | 480 |
|---|
| Supplement SB flag | Yes |
|---|
| Grid profile flag | Y* |
|---|
| Listing date | Jul 21, 2026 |
|---|
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|
| Minimum | 92.487467 | 95.2327 | 95.7798 | 95.841767 | 95.766867 | 95.399233 |
|---|
| Nominal | 92.856367 | 95.462967 | 96.117733 | 96.137567 | 96.3349 | 96.010767 |
|---|
| Maximum | 92.487833 | 95.063033 | 95.7129 | 96.021833 | 95.908967 | 95.744667 |
|---|
HNA2-S11G5 {240V, 11.5kW}
HNA2-S11G5 {240V, 11.5kW} listed figures| AC voltage (V) | 240 |
|---|
| Continuous output (kW) | 11.34938 |
|---|
| Weighted efficiency (%) | 96 |
|---|
| Night draw (W) | 14.23 |
|---|
| Output at 40°C (kW) | Not stated |
|---|
| Test DC voltage, minimum (V) | 250 |
|---|
| Test DC voltage, nominal (V) | 375 |
|---|
| Test DC voltage, maximum (V) | 480 |
|---|
| Supplement SB flag | Yes |
|---|
| Grid profile flag | Y* |
|---|
| Listing date | Jul 21, 2026 |
|---|
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|
| Minimum | 94.727 | 96.115467 | 96.215233 | 96.170933 | 95.6922 | 95.039167 |
|---|
| Nominal | 95.265767 | 96.647767 | 96.8035 | 96.776767 | 96.317767 | 95.601533 |
|---|
| Maximum | 94.613167 | 96.121667 | 96.405933 | 96.407033 | 96.039933 | 95.540867 |
|---|
Maker or retailer figures
No publishable maker or retailer figures are held for this model. Figures may be published elsewhere.
Stored retail listings
No stored retail listing is held for this model.
Not covered
Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.