Inverter List

Inverters

Eternalplanet HNA2-S11G5

Eternalplanet inverters · Hybrid-listed

Eternalplanet HNA2-S11G5 is a hybrid-listed inverter on California's eligible inverter list in 7 voltage options: 5.0315–11.34938 kW continuous output and 96–97% weighted efficiency at 208 and 240 V. Listed since Jul 21, 2026.

No recorded installation count is held for this model. A missing count does not mean no installations.

Listed figures by voltage option

California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.

HNA2-S11G5 {208V, 9.9kW}

HNA2-S11G5 {208V, 9.9kW} listed figures
AC voltage (V)208
Continuous output (kW)9.9
Weighted efficiency (%)95.5
Night draw (W)19.77
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)250
Test DC voltage, nominal (V)360
Test DC voltage, maximum (V)480
Supplement SB flagYes
Grid profile flagY*
Listing dateJul 21, 2026
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.07726795.772995.512895.24606795.21743394.565067
Nominal94.694696.18003396.35383396.31923395.64523395.1092
Maximum94.023995.64483395.974895.89243395.594.999667

HNA2-S11G5 {240V, 7.6kW}

HNA2-S11G5 {240V, 7.6kW} listed figures
AC voltage (V)240
Continuous output (kW)7.6
Weighted efficiency (%)96.5
Night draw (W)20.14
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)250
Test DC voltage, nominal (V)375
Test DC voltage, maximum (V)480
Supplement SB flagYes
Grid profile flagY*
Listing dateJul 21, 2026
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum93.27393395.647596.20836796.23583396.08863395.7839
Nominal93.69973395.998396.63926796.805796.67676796.4222
Maximum93.47873395.61193396.25983396.56833396.453596.186967

HNA2-S11G5 {240V, 5.8kW}

HNA2-S11G5 {240V, 5.8kW} listed figures
AC voltage (V)240
Continuous output (kW)5.8122
Weighted efficiency (%)96
Night draw (W)20.14
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)250
Test DC voltage, nominal (V)375
Test DC voltage, maximum (V)480
Supplement SB flagYes
Grid profile flagY*
Listing dateJul 21, 2026
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum91.69146794.908395.85006796.16616796.28313396.1082
Nominal92.487495.37936796.201596.78326796.835696.708367
Maximum92.00246794.96596795.82753396.50986796.48546796.455433

HNA2-S11G5 {208V, 5.0kW}

HNA2-S11G5 {208V, 5.0kW} listed figures
AC voltage (V)208
Continuous output (kW)5.0315
Weighted efficiency (%)95.5
Night draw (W)19.77
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)250
Test DC voltage, nominal (V)360
Test DC voltage, maximum (V)480
Supplement SB flagYes
Grid profile flagY*
Listing dateJul 21, 2026
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum90.64813394.22046795.28436795.81801695.71896795.6238
Nominal91.471494.607295.664296.23336796.12632296.176333
Maximum91.268294.50466795.38346795.936295.96986795.883833

HNA2-S11G5 {240V, 9.6kW}

HNA2-S11G5 {240V, 9.6kW} listed figures
AC voltage (V)240
Continuous output (kW)9.63
Weighted efficiency (%)96
Night draw (W)20.14
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)250
Test DC voltage, nominal (V)375
Test DC voltage, maximum (V)480
Supplement SB flagYes
Grid profile flagY*
Listing dateJul 21, 2026
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.168595.97006796.25603396.19656795.84523395.4484
Nominal94.66276796.32683396.72666796.77296.42295.9912
Maximum94.16883395.99416796.486496.53723396.28436795.775467

HNA2-S11G5 {208V, 6.6kW}

HNA2-S11G5 {208V, 6.6kW} listed figures
AC voltage (V)208
Continuous output (kW)6.68
Weighted efficiency (%)96
Night draw (W)19.77
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)250
Test DC voltage, nominal (V)360
Test DC voltage, maximum (V)480
Supplement SB flagYes
Grid profile flagY*
Listing dateJul 21, 2026
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum92.48746795.232795.779895.84176795.76686795.399233
Nominal92.85636795.46296796.11773396.13756796.334996.010767
Maximum92.48783395.06303395.712996.02183395.90896795.744667

HNA2-S11G5 {240V, 11.5kW}

HNA2-S11G5 {240V, 11.5kW} listed figures
AC voltage (V)240
Continuous output (kW)11.34938
Weighted efficiency (%)96
Night draw (W)14.23
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)250
Test DC voltage, nominal (V)375
Test DC voltage, maximum (V)480
Supplement SB flagYes
Grid profile flagY*
Listing dateJul 21, 2026
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.72796.11546796.21523396.17093395.692295.039167
Nominal95.26576796.64776796.803596.77676796.31776795.601533
Maximum94.61316796.12166796.40593396.40703396.03993395.540867

Maker or retailer figures

No publishable maker or retailer figures are held for this model. Figures may be published elsewhere.

Stored retail listings

No stored retail listing is held for this model.

Not covered

Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.