Inverter List

Inverters

Generac PM-820

Generac inverters · Microinverter

Generac PM-820 is a microinverter on California's eligible inverter list in 2 voltage options: 820 W continuous output and 97% weighted efficiency at 208 and 240 V. Listed since Aug 1, 2025.

The recorded count is fewer than five systems. Other installation details are withheld for this small group.

Listed figures by voltage option

California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.

PM-820 {208V}

PM-820 {208V} listed figures
AC voltage (V)208
Continuous output (kW)0.82
Weighted efficiency (%)96.5
Night draw (W)0.35
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)31.5
Test DC voltage, nominal (V)37.5
Test DC voltage, maximum (V)40
Supplement SB flagYes
Grid profile flagY*
Listing dateAug 1, 2025
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum93.9196.6197.1297.296.8696.38
Nominal92.049696.7497.196.9696.6
Maximum91.1695.5696.5597.0196.9996.74

PM-820 {240V}

PM-820 {240V} listed figures
AC voltage (V)240
Continuous output (kW)0.82
Weighted efficiency (%)97
Night draw (W)0.39
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)31.5
Test DC voltage, nominal (V)37.5
Test DC voltage, maximum (V)40
Supplement SB flagYes
Grid profile flagY*
Listing dateAug 1, 2025
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.1896.6397.1997.3297.0196.54
Nominal92.6196.0296.8397.2497.1596.85
Maximum91.6595.6496.6697.1897.1996.99

Maker or retailer figures

Published figures and their conditions
PropertyValueUnitBasis and scopeDocument
Supplement SB Yes—Maker listing claim · US · this model
PM-820
Certifications
Generac Power Systems document
Recorded Oct 12, 2026
Efficiency 97.1%Peak · US · this model
PM-820 {208V}
Peak Inverter Efficiency @ 208V
Generac Power Systems document
Recorded Oct 12, 2026
Night draw 0.4WNight · US · this model
PM-820
Nighttime Power Consumption (After Commissioning)
Generac Power Systems document
Recorded Oct 12, 2026
Efficiency 97.3%Peak · US · this model
PM-820 {240V}
Peak Inverter Efficiency @ 240V
Generac Power Systems document
Recorded Oct 12, 2026
Warranty 25yearsStandard · US · this model
PM-820
Microinverter Warranty
Generac Power Systems document
Recorded Oct 12, 2026
AC power 0.82kVAContinuous · US · this model
PM-820 {240V}
Max. Continuous Output Power @ 240V
Generac Power Systems document
Recorded Oct 12, 2026
Efficiency 97%California weighted · US · this model
PM-820 {208V}
Generac Power Systems document
Recorded Oct 12, 2026
Tracker voltage 31-42.5VOperating · US · this model
PM-820
MPPT Voltage Tracking Range
Generac Power Systems document
Recorded Oct 12, 2026
AC power 0.82kVAContinuous · US · this model
PM-820 {208V}
Max. Continuous Output Power @ 208V
Generac Power Systems document
Recorded Oct 12, 2026
Efficiency 97%California weighted · US · this model
PM-820 {240V}
Generac Power Systems document
Recorded Oct 12, 2026

Published values that differ

The pairs below use the stated comparison rules. Different values do not establish which value is right. Peak efficiency is compared with the highest listed test point, not with weighted efficiency.

Comparable values outside rounding tolerance
PropertyVoltage optionListed basisUnitListedMaker or retailer
EfficiencyPM-820 {208V}california weighted published%96.597
Night drawPM-820 {208V}nightW0.350.4

Stored retail listings

No stored retail listing is held for this model.

Not covered

Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.