Hoymiles HMS-700-2T-NA
Hoymiles inverters · Microinverter
Hoymiles HMS-700-2T-NA is a microinverter on California's eligible inverter list: 642.2006 W continuous output and 97% weighted efficiency at 240 V. Listed since Mar 1, 2021.
The recorded count is fewer than five systems. Other installation details are withheld for this small group.
Listed figures by voltage option
California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.
HMS-700-2T-NA {240V}
| AC voltage (V) | 240 |
|---|---|
| Continuous output (kW) | 0.642201 |
| Weighted efficiency (%) | 96.5 |
| Night draw (W) | 0.11 |
| Output at 40°C (kW) | Not stated |
| Test DC voltage, minimum (V) | 33 |
| Test DC voltage, nominal (V) | 42 |
| Test DC voltage, maximum (V) | 48 |
| Supplement SB flag | Yes |
| Grid profile flag | Y* |
| Listing date | Mar 1, 2021 |
Efficiency across test conditions
| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|---|---|
| Minimum | 94.72881 | 96.076041 | 96.379371 | 96.458457 | 96.523351 | 96.02055 |
| Nominal | 94.784289 | 95.803244 | 96.452829 | 96.463312 | 96.48819 | 96.117357 |
| Maximum | 94.297972 | 95.80592 | 96.399222 | 96.492728 | 96.489873 | 96.124101 |
Maker or retailer figures
| Property | Value | Unit | Basis and scope | Document |
|---|---|---|---|---|
| AC power | 0.7 | kVA | Surge · US · this model HMS-700-2T-NA Peak output power (VA) | Hoymiles document Recorded Oct 12, 2026 |
| Tracker voltage | 16-60 | V | Operating · US · this model HMS-700-2T-NA MPPT voltage range (V) | Hoymiles document Recorded Oct 12, 2026 |
| Power trackers | 2 | — | Count · US · this model HMS-700-2T-NA Number of MPPTs | Hoymiles document Recorded Oct 12, 2026 |
| Night draw | < 0.05 | W | Night · US · this model HMS-700-2T-NA Night power consumption (mW) | Hoymiles document Recorded Oct 12, 2026 |
| AC power | 0.638 | kVA | Continuous · US · this model HMS-700-2T-NA Maximum continuous output power (VA) | Hoymiles document Recorded Oct 12, 2026 |
| Rapid shutdown | Conforms with NEC-2017 and NEC-2020 Article 690.12 | — | Code claim · US · this model HMS-700-2T-NA NEC 690.12 | Hoymiles document Recorded Oct 12, 2026 |
| Supplement SB | Yes | — | Maker listing claim · US · this model HMS-700-2T-NA UL 1741 SB | Hoymiles document Recorded Oct 12, 2026 |
| Efficiency | 96.7 | % | Peak · US · this model HMS-700-2T-NA | Hoymiles document Recorded Oct 12, 2026 |
Published values that differ
The pairs below use the stated comparison rules. Different values do not establish which value is right. Peak efficiency is compared with the highest listed test point, not with weighted efficiency.
| Property | Voltage option | Listed basis | Unit | Listed | Maker or retailer |
|---|---|---|---|---|---|
| AC power | HMS-700-2T-NA {240V} | ac continuous unity pf | kVA | 0.642201 | 0.638 |
Stored retail listings
No stored retail listing is held for this model.
Not covered
Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.