Inverter List

Inverters

HYXiPower HYX-M1000-S

HYXiPower inverters · Microinverter

HYXiPower HYX-M1000-S is a microinverter on California's eligible inverter list in 2 voltage options: 0.993798–1.062156 kW continuous output and 97% weighted efficiency at 208 and 240 V. Listed since Feb 21, 2024.

No recorded installation count is held for this model. A missing count does not mean no installations.

Listed figures by voltage option

California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.

HYX-M1000-S {208V}

HYX-M1000-S {208V} listed figures
AC voltage (V)208
Continuous output (kW)0.993798
Weighted efficiency (%)96.5
Night draw (W)0.11
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)35
Test DC voltage, nominal (V)42
Test DC voltage, maximum (V)50
Supplement SB flagYes
Grid profile flagN
Listing dateFeb 21, 2024
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum94.838995.16317496.35850896.89632496.23112596.32524
Nominal95.40592496.39410896.61498796.91099297.2046295.618455
Maximum95.87431595.09633596.5120696.65984696.55881897.132232

HYX-M1000-S {240V}

HYX-M1000-S {240V} listed figures
AC voltage (V)240
Continuous output (kW)1.062156
Weighted efficiency (%)96.5
Night draw (W)0.13
Output at 40°C (kW)Not stated
Test DC voltage, minimum (V)35
Test DC voltage, nominal (V)42
Test DC voltage, maximum (V)50
Supplement SB flagYes
Grid profile flagN
Listing dateFeb 21, 2024
Efficiency across test conditions
Efficiency (%) by DC test voltage and output load
DC test voltage10% load20% load30% load50% load75% load100% load
Minimum96.20134196.42707996.23333995.90931896.90554696.231801
Nominal95.77705796.63135296.62777296.31443396.58519896.211543
Maximum95.0948496.58640596.63710496.09278197.24784296.231925

Maker or retailer figures

Published figures and their conditions
PropertyValueUnitBasis and scopeDocument
AC power 1kVABasis not stated · global · this model
HYX-M1000-S
Nominal Output Power
HYXiPower (Zhejiang Hyxi Technology) document
Recorded Oct 12, 2026
Night draw< 0.03WNight · global · this model
HYX-M1000-S
Night-time Power Loss
HYXiPower (Zhejiang Hyxi Technology) document
Recorded Oct 12, 2026
Efficiency 96.7%Peak · global · this model
HYX-M1000-S
Peak Efficiency
HYXiPower (Zhejiang Hyxi Technology) document
Recorded Oct 12, 2026
Supplement SB Yes—Maker listing claim · US · this model
HYX-M1000-S
Applicable requirements (CSA certificate)
HYXiPower (Zhejiang Hyxi Technology) document
Recorded Oct 12, 2026
Warranty 12yearsStandard · global · this model
HYX-M1000-S
Warranty ... standard
HYXiPower (Zhejiang Hyxi Technology) document
Recorded Oct 12, 2026
Tracker voltage 16-60VOperating · global · this model
HYX-M1000-S
Min./Max. MPPT Voltage
HYXiPower (Zhejiang Hyxi Technology) document
Recorded Oct 12, 2026
Warranty 25yearsExtended · global · this model
HYX-M1000-S
Warranty ... optional
HYXiPower (Zhejiang Hyxi Technology) document
Recorded Oct 12, 2026

Stored retail listings

No stored retail listing is held for this model.

Not covered

Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.