HYXiPower HYX-M2000-S-NA
HYXiPower inverters · Microinverter
HYXiPower HYX-M2000-S-NA is a microinverter on California's eligible inverter list in 2 voltage options: 1.91–1.914 kW continuous output and 96–97% weighted efficiency at 208 and 240 V. Listed since Jun 11, 2024.
No recorded installation count is held for this model. A missing count does not mean no installations.
Listed figures by voltage option
California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.
HYX-M2000-S-NA {240V}
| AC voltage (V) | 240 |
|---|---|
| Continuous output (kW) | 1.91 |
| Weighted efficiency (%) | 96 |
| Night draw (W) | 0.034 |
| Output at 40°C (kW) | Not stated |
| Test DC voltage, minimum (V) | 35 |
| Test DC voltage, nominal (V) | 42 |
| Test DC voltage, maximum (V) | 50 |
| Supplement SB flag | Yes |
| Grid profile flag | Y* |
| Listing date | Jun 11, 2024 |
Efficiency across test conditions
| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|---|---|
| Minimum | 95.800085 | 95.873966 | 95.618905 | 95.498924 | 96.26004 | 95.731658 |
| Nominal | 95.190768 | 95.648992 | 95.212244 | 95.852974 | 96.247682 | 95.846226 |
| Maximum | 96.132789 | 95.114349 | 95.710134 | 96.007859 | 95.857135 | 95.708162 |
HYX-M2000-S-NA {208V}
| AC voltage (V) | 208 |
|---|---|
| Continuous output (kW) | 1.914 |
| Weighted efficiency (%) | 97 |
| Night draw (W) | 0.026 |
| Output at 40°C (kW) | Not stated |
| Test DC voltage, minimum (V) | 35 |
| Test DC voltage, nominal (V) | 42 |
| Test DC voltage, maximum (V) | 50 |
| Supplement SB flag | Yes |
| Grid profile flag | Y* |
| Listing date | Jun 11, 2024 |
Efficiency across test conditions
| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|---|---|
| Minimum | 95.615927 | 96.83232 | 97.528225 | 97.208379 | 96.513615 | 94.823027 |
| Nominal | 94.954553 | 96.503471 | 97.059634 | 97.42515 | 96.788917 | 95.513949 |
| Maximum | 93.946461 | 96.088021 | 96.770037 | 97.478794 | 96.910546 | 96.807498 |
Maker or retailer figures
| Property | Value | Unit | Basis and scope | Document |
|---|---|---|---|---|
| Night draw | < 0.03 | W | Night · US · this model HYX-M2000-S-NA Night-time Power Loss | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
| AC power | 1.92 | kVA | Continuous · US · this model HYX-M2000-S-NA Max. Continuous Output Power | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
| Tracker voltage | 16-60 | V | Operating · US · this model HYX-M2000-S-NA Min./Max. MPPT Voltage | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
| Efficiency | 96.7 | % | Peak · US · this model HYX-M2000-S-NA | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
| Warranty | 25 | years | Standard · US · this model HYX-M2000-S-NA Warranty | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
| Supplement SB | Yes | — | Maker listing claim · US · this model HYX-M2000-S-NA Safety and EMC Compliance | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
| Supplement SB | Yes | — | Maker listing claim · US · this model HYX-M2000-S-NA Applicable requirements (CSA certificate) | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
| Rapid shutdown | NEC-2017 & NEC-2020 & NEC-2023 Article 690.12 Rapid shutdown of PV systems on Buildings | — | Code claim · US · this model HYX-M2000-S-NA Safety and EMC Compliance | HYXiPower (Zhejiang Hyxi Technology) document Recorded Oct 12, 2026 |
Published values that differ
The pairs below use the stated comparison rules. Different values do not establish which value is right. Peak efficiency is compared with the highest listed test point, not with weighted efficiency.
| Property | Voltage option | Listed basis | Unit | Listed | Maker or retailer |
|---|---|---|---|---|---|
| Efficiency | HYX-M2000-S-NA {240V} | matrix peak | % | 96.26004 | 96.7 |
| Efficiency | HYX-M2000-S-NA {208V} | matrix peak | % | 97.528225 | 96.7 |
| AC power | HYX-M2000-S-NA {240V} | ac continuous unity pf | kVA | 1.91 | 1.92 |
Stored retail listings
No stored retail listing is held for this model.
Not covered
Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.