Senergy SE 11K4HB-210-T2/UL
Senergy inverters · Hybrid-listed
Senergy SE 11K4HB-210-T2/UL is a hybrid-listed inverter on California's eligible inverter list in 2 voltage options: 10.14–10.186 kW continuous output and 97% weighted efficiency at 208 and 240 V. Listed since Jul 22, 2024.
The recorded count is fewer than five systems. Other installation details are withheld for this small group.
Listed figures by voltage option
California's eligible inverter list restates manufacturer-submitted test results. These are not independent measurements of a unit in a home.
SE 11K4HB-210-T2/UL {240V}
| AC voltage (V) | 240 |
|---|---|
| Continuous output (kW) | 10.14 |
| Weighted efficiency (%) | 96.5 |
| Night draw (W) | 16.94 |
| Output at 40°C (kW) | Not stated |
| Test DC voltage, minimum (V) | 200 |
| Test DC voltage, nominal (V) | 360 |
| Test DC voltage, maximum (V) | 480 |
| Supplement SB flag | Yes |
| Grid profile flag | Y* |
| Listing date | Jul 22, 2024 |
Efficiency across test conditions
| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|---|---|
| Minimum | 92.91 | 95.48 | 96.12 | 96.56 | 96.36 | 96.1 |
| Nominal | 93.66 | 96.02 | 96.72 | 97.07 | 96.88 | 96.68 |
| Maximum | 94.07 | 96.17 | 96.67 | 96.99 | 96.82 | 96.56 |
SE 11K4HB-210-T2/UL {208V}
| AC voltage (V) | 208 |
|---|---|
| Continuous output (kW) | 10.186 |
| Weighted efficiency (%) | 96.5 |
| Night draw (W) | 16.67 |
| Output at 40°C (kW) | Not stated |
| Test DC voltage, minimum (V) | 200 |
| Test DC voltage, nominal (V) | 360 |
| Test DC voltage, maximum (V) | 480 |
| Supplement SB flag | Yes |
| Grid profile flag | Y* |
| Listing date | Jul 22, 2024 |
Efficiency across test conditions
| DC test voltage | 10% load | 20% load | 30% load | 50% load | 75% load | 100% load |
|---|---|---|---|---|---|---|
| Minimum | 93.05 | 95.58 | 96.24 | 96.66 | 96.45 | 96.2 |
| Nominal | 93.72 | 96.07 | 96.82 | 97.15 | 96.96 | 96.78 |
| Maximum | 94.05 | 96.25 | 96.79 | 97.12 | 96.92 | 96.66 |
Maker or retailer figures
| Property | Value | Unit | Basis and scope | Document |
|---|---|---|---|---|
| Efficiency | 96.5 | % | California weighted · US · this model SE 11K4HB-210-T2/UL | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| Tracker voltage | 70-540 | V | Operating · US · this model SE 11K4HB-210-T2/UL MPPT Operating Voltage Range | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| Efficiency | 98 | % | Peak · US · this model SE 11K4HB-210-T2/UL Max. Efficiency (PV to AC) | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| AC power | 11.4 | kW | Basis not stated · US · this model SE 11K4HB-210-T2/UL Max. AC Output Power (PF=1) | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| Warranty | 10 | years | Extended · US · this model SE 11K4HB-210-T2/UL 10 Years (Optional) | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| AC power | 20 | kVA | Surge (1 seconds) · US · this model SE 11K4HB-210-T2/UL Peak Output Apparent Power(1s) (back-up output) | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| Warranty | 5 | years | Standard · US · this model SE 11K4HB-210-T2/UL Warranty 5 Years | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| Supplement SB | Yes | — | Maker listing claim · US · this model SE 11K4HB-210-T2/UL Grid Code: UL 1741SB | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| DC input | 15,000 | W | DC maximum · US · this model SE 11K4HB-210-T2/UL Max. PV Usable Power | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| Power trackers | 3 | — | Count · US · this model SE 11K4HB-210-T2/UL Nos. of MPPT | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
| AC power | 11.4 | kVA | Apparent power · US · this model SE 11K4HB-210-T2/UL Max. AC Output Apparent Power | Shenzhen Senergy Technology document Recorded Oct 12, 2026 |
Published values that differ
The pairs below use the stated comparison rules. Different values do not establish which value is right. Peak efficiency is compared with the highest listed test point, not with weighted efficiency.
| Property | Voltage option | Listed basis | Unit | Listed | Maker or retailer |
|---|---|---|---|---|---|
| Efficiency | SE 11K4HB-210-T2/UL {240V} | matrix peak | % | 97.07 | 98 |
| Efficiency | SE 11K4HB-210-T2/UL {208V} | matrix peak | % | 97.15 | 98 |
Stored retail listings
No stored retail listing is held for this model.
Not covered
Figures published by the maker or on a retailer's product page cover 410 of 1,086 residential listed models (about 38%). Stored retail listings cover 154. Missing figures are not zero. Reliability, replacement fit and battery compatibility are not established. Coverage and method.